Lineární vedení Schneeberger MINIRAIL - EN
46 Ua 1 + Ua 0 + Ua 2 + Ua 2 - Ua 0 - Ua 1 - 2.3V 100μm + - + - + - 0.5V ≈100μm 10 MINISCALE PLUS Product Overview Single-ended Signals Analog Interface Module Output Differential Signals Reference point Sine Cosine Reference 10.2.5 Signal Processing Further information about signal processing is available from the download section of our website www.schneeberger.com. Analog output format: Differential, sin/cos analog signals with reference pulse 1 Vpp (at 120 Ω). The incremental signals sine and cosine are shifted 90° and correlated with the markings on the encoded scale. An electrical signal period (360°) corresponds precisely to the scale increment of the dimensional scale, which is 100 µm. The reference pulse always marks electronically the same section of the path of the sine and cosine signals. The point of intersection of the two signals within the reference pulse therefore marks a precisely defined position on the dimensional scale. The sine signal either lags behind the cosine signal or occurs before it, depending on the direction of movement.