Lineární jednotky - EN

145 Possible arrangement of Proximity Switches 8 and Proximity- Switch Cams 8: The Proximity-Switch Cams run through the Timing-Belt Reverse Units. Particularly suitable when used with the drive end Timing Belt Reverse Unit for simplifying cable routing between the drive unit, Proximity Switch and motor control unit. Possible arrangement of Proximity Switches 8 and Proximity-Switch Cams 8: The Proximity-Switch Cams do not run through the Timing-Belt Reverse Units. When using a system that reverses the timing belt via contact with its flat side (Timing-Belt Counter-Reverse Unit 8 R25/ Timing-Belt Reverse Unit 8 80 R25 with emergence 40 mm), Proximity-Switch Cams 8 must not pass through the Timing-Belt Reverse Units. In this case, Proximity Switches 8 and Proximity- Switch Cams 8 must be positioned to prevent this from happening. Proximity Switch ■ ■ Inductive proximity switch for added safety in linear drives ■ ■ Installed in Line 8 groove (Proximity Switch 8) ■ ■ Installed in Timing-Belt Reverse Unit (Proximity Switch M8) Proximity Switch M8 is a versatile device for limiting the ter- minal position or for reference on Linear Units with timing-belt drives. It is available with a permanent or plug-in connecting cable. The Proximity-Switch Cam is used to mark the terminal posi- tion and/or the reference point of the unit on the Timing Belt. The Proximity-Switch Fastening Set is used to position and attach inductive Proximity Switches M8 on the Timing-Belt Reverse Units. Proximity-Switch Connecting Cable in plug-in design with integrated LEDs for display- ing the switch function and operating voltage. ACCESSORIES

RkJQdWJsaXNoZXIy NTk1NjQ0