Stavebnicový systém MB 9 - EN

693 19 The total load of a screw connection comprises the sum of the pre-tensioning force and the operating load! The permissible operating load is based on a safety factor of 1.5. T E C H N I C A L D A T A T-Slot Nuts Order No. Recommended tightening torque Permissible operating load 10 St M10, heavy 0.0.624.95 65 Nm 7,000 N * 10 St M8, heavy 0.0.624.97 34 Nm 6,000 N * 10 St M10 0.0.625.02 46 Nm 7,000 N * 10 St M8 0.0.625.04 34 Nm 6,000 N * 10 St M6 0.0.625.06 14 Nm 3,500 N * 12 St M12, heavy 0.0.003.68 100 Nm 10,000 N * 12 St M10, heavy 0.0.003.67 65 Nm 10,000 N * 12 St M8, heavy 0.0.003.66 34 Nm 6,000 N * 12 St M12 0.0.003.65 80 Nm 10,000 N * 12 St M10 0.0.003.64 46 Nm 10,000 N * 12 St M8 0.0.003.63 34 Nm 6,000 N * 12 St M6 0.0.003.72 14 Nm 3,500 N * Maximum load achievable in standard Profile only. Check profile properties if using e.g. Profile Light or Profile E.